Products  Furnace, Carbon content meter

high temp muffle furnace 1500℃ (22L)

Model: high temp muffle furnace 1500℃
Producer: SH Scientific-Korea
Giá: Contact
High temperature furnace with SiC rod heating with revolving door. Great for testing metal samples. Built-in programmable controller. 5 samples and 9 segments/sample. A total of 45 segments. Recommended ideal running ...

Product Application

Used in the following areas:
●  Destructive testing laboratories perform heat treatment of ceramic, alloy, titanium, etc. for aerospace and metal manufacturing.
●  Build companies that turn metal energy like nickel alloys into sintered materials by sintering.
●  Material technology suppliers develop polymer composites and graphene materials.
●  Aerospace companies perform cyclic oxidation testing from 1700C to room temperature in a controlled atmosphere.
●  Medical and healthcare companies need to analyze ash and content through material combustion.
●  Companies innovate materials sintered in a vacuum or in an inert gas.
● Companies with surface and subsea spray systems need vacuum furnaces for the long-term softening, tempering and hardening cycles of Inconel 718 tubes.
●  Analytical research laboratories perform various material tests by heat treatment.
●  Manufacturers of medical implants annealing alloy powders.
●  Material scientists at universities make sintered materials such as ceramic parts derived from polymers.
●  Scientific engineer of solid oxide fuel cell (SOFC) processing.
●  Environmental and chemists who need to burn materials.
● Regulatory compliance service providers in the areas of hazardous waste heat treatment, air licensing, air pollution control, contaminated soil remediation, and hazardous waste management.
●  Manufacturers of metal parts need vacuum welding and heat treatment of steel.
●  Water treatment companies test the glass content in FRP (fiber-reinforced polymer) products according to ASTM D2584.
●  Semiconductor manufacturers annealing Gallium nitride (GaN) semiconductor wafers.
●  Technical companies perform curing and sintering solutions in porous ceramic tubes.
●  Civil engineers need to burn land.
●  University laboratories annealing Si wafers under vacuum conditions.
● Chemical laboratories perform heat treatments (stabilization in air and carbonization in argon) of carbon nanofiber precursors.
●  Marine equipment manufacturers analyze ash content in marine HFO (Heavy Fuel Oil).
●  Graphene solutions companies manufacture graphene-based materials using the CVD (Chemical Vapor Deposition) method. CVD . furnace
●  Manufacturer of solid-state batteries with polymer electrolyte, oxide electrolyte, sulfide electrolyte, phosphate electrolyte, etc.

Specifications

Model SH-FU-22MH
Max temperature 1500
Continuous running temperature 1350
Chamber volume 22liters
Controller Programmable controller
Sensor R type
Heater 9.6kW
Heating element SiC
Insulation Ceramic
Power supply 220V, 50/60Hz, 1p, 42A
Net weight 147kg
Chamber size 250x350x250mm
External size 920x710x970mm

Standard

Video

Please contact us for advice and support
⇒  Mr. Ba: 0948.27.99.88

⇒  Or leave a message and we will call you directly. Thank you very much!
Other products
high temp muffle furnace 1500℃ (4.5L)
Model: high temp muffle furnace 1500℃
Producer: SH Scientific-Korea
  • High temperature furnace with SiC rod heating with revolving door. Great for testing metal samples. Built-in programmable controller. 5 samples and 9 segments/sample. A total of 45 segments. Recommended ideal running temperature is below 1350 ℃ * 24 hours continuous running. Heating from 2 sides and anti-warping vertical SiC rod. easy replacement. Excellent air release thanks to the air outlet on the top of the chamber, i.e. polymer resin. Dual shell and low surface temperature. Ceramic fiber materials are not classified as carcinogenic. High temperature uniformity (+/-4%). Fast heating and well maintained. SCR operation and programmable control for low noise operation and precise temperature control (+/- 1 ℃ ). Atmosphere available with optional flow meter
Buy product
high temp muffle furnace 1500℃ (11L)
Model: high temp muffle furnace 1500℃
Producer: SH Scientific-Korea
  • High temperature furnace with SiC rod heating with revolving door. Great for testing metal samples. Built-in programmable controller. 5 samples and 9 segments/sample. A total of 45 segments. Recommended ideal running temperature is below 1350 ℃ * 24 hours continuous running. Heating from 2 sides and anti-warping vertical SiC rod. easy replacement. Excellent air release thanks to the air outlet on the top of the chamber, i.e. polymer resin. Dual shell and low surface temperature. Ceramic fiber materials are not classified as carcinogenic. High temperature uniformity (+/-4%). Fast heating and well maintained. SCR operation and programmable control for low noise operation and precise temperature control (+/- 1 ℃ ). Atmosphere available with optional flow meter
Buy product
 high temp muffle furnace 1700℃ (22L)
Model: high temp muffle furnace 1700℃ (22L)
Producer: SH Scientific-Korea
  • High temperature furnace with MoSi2 rod heated to 1700°C. Great for metal sample testing and sintering. Recommended ideal running temperature is below 1550 ℃ * 24 hours continuous running. Heating from 2 sides and anti-warping vertical MoSi2 bar. easy replacement. Excellent air release thanks to the air outlet on the top of the chamber, i.e. polymer resin. Dual shell and low surface temperature. Ceramic fiber materials are not classified as carcinogenic. High temperature uniformity (+/-4%). Fast heating and well maintained. SCR operation and programmable control for low noise operation and precise temperature control (+/- 1 ℃ )
Buy product
 high temp muffle furnace 1700℃ (11L)
Model: high temp muffle furnace 1700℃
Producer: SH Scientific-Korea
  • High temperature furnace with MoSi2 rod heated to 1700°C. Great for metal sample testing and sintering. Recommended ideal running temperature is below 1550 ℃ * 24 hours continuous running. Heating from 2 sides and anti-warping vertical MoSi2 bar. easy replacement. Excellent air release thanks to the air outlet on the top of the chamber, i.e. polymer resin. Dual shell and low surface temperature. Ceramic fiber materials are not classified as carcinogenic. High temperature uniformity (+/-4%). Fast heating and well maintained. SCR operation and programmable control for low noise operation and precise temperature control (+/- 1 ℃ )
Buy product
Black Carbon Content Meter
Model: SH-FU-50STG-WG
Producer: SH Scientific-Korea
•   Carbon black meter is used to determine the content of carbon black in geomembranes, polyolefin plastic pipes (polyethylene, polypropylene and polybutylene) and materials used specifically to manufacture plastic pipes and fittings. and synthetic materials.
Buy product
high temp muffle furnace 1700℃ (4.5L)
Model: high temp muffle furnace 1700℃
Producer: SH Scientific-Korea
  • High temperature furnace with MoSi2 rod heated to 1700°C. Great for metal sample testing and sintering. Recommended ideal running temperature is below 1550 ℃ * 24 hours continuous running. Heating from 2 sides and anti-warping vertical MoSi2 bar. easy replacement. Excellent air release thanks to the air outlet on the top of the chamber, i.e. polymer resin. Dual shell and low surface temperature. Ceramic fiber materials are not classified as carcinogenic. High temperature uniformity (+/-4%). Fast heating and well maintained. SCR operation and programmable control for low noise operation and precise temperature control (+/- 1 ℃ )
Buy product
high temp muffle furnace 1500℃ (36L)
Model: high temp muffle furnace 1500℃
Producer: SH Scientific-Korea
  • High temperature furnace with SiC rod heating with revolving door. Great for testing metal samples. Built-in programmable controller. 5 samples and 9 segments/sample. A total of 45 segments. Recommended ideal running temperature is below 1350 ℃ * 24 hours continuous running. Heating from 2 sides and anti-warping vertical SiC rod. easy replacement. Excellent air release thanks to the air outlet on the top of the chamber, i.e. polymer resin. Dual shell and low surface temperature. Ceramic fiber materials are not classified as carcinogenic. High temperature uniformity (+/-4%). Fast heating and well maintained. SCR operation and programmable control for low noise operation and precise temperature control (+/- 1 ℃ ). Atmosphere available with optional flow meter
Buy product
Customers
Partners
Zalo
Hotline
Bản đồ
Youtube